Public Comment 3

No Draft Myanmar Standards Abstract/Scope Committee Close Date Action Comment
40 DMMS ISO 68 – 1: 1998 (general purpose screw threads – Basic profile – Part 1 : Metric screw threads) This part of ISO 68 specifies the basic profile for ISO general purpose metric screw threads (M). TC14-Technical Committee for Mechanical
39 DMMS ISO 2000:2014 Rubber, raw natural – Guidelines for the specification of technically specified rubber(TSR) This International Standard provides guidance on the specification of technically specified rubber (TSR). A grading system is proposed, based on the origin of the natural rubber content and on properties exhibited by the rubber. This International Standard is intended for use by parties involved in the procurement of TSR, and is intended to form a basis from which requirements for a particular case may be more closely specified. As such, it describes a number of criteria that need to be the subject of appropriate agreement between the interested parties. TC11-Technical Committee for Rubber-based product
38 DMMS ASEAN Stan 18 : 2010 – သခွားမွှေးသီးစံချိန်စံညွှန်း TC7-Technical Committee for Agro-based
37 DMMS Codex Stan 204 : 1997 – မင်းဂွတ်သီးစံချိန်စံညွှန်း TC7-Technical Committee for Agro-based
36 DMMS Codex Stan 317 : 2014 – ဒူးရင်းသီးစံချိန်စံညွှန်း TC7-Technical Committee for Agro-based
35 DMMS IEC 62552-3 : 2015 Household refrigeration appliances- Characteristics and test methods Part : 3 Energy consumption and volume This part of IEC 62552 specifies the essential characteristics of household and similar refrigerating appliances, cooled by internal nature convection or forced air circulation and establishes test methods for checking the characteristics.
This part of IEC 62552 describes the methods for the determination of energy consumption characteristics and defines how these can be assembled to estimate energy consumption under different usage and climate conditions. This part of IEC 62552 also defines the determination of volume.
TC1-Technical Committee for Electrical and Electronic
34 DMMS IEC 62552-2 : 2015 Household refrigeration appliances- Characteristics and test methods Part : 2 Performance Requirements This part of IEC 62552 specifies the essential characteristics of household refrigerating appliances, cooled by internal nature convection or forced air circulation and establishes test methods for checking the characteristics.
This part of IEC 62552 describes the methods for the determination of performance requirements. Although there is some commonality in the set-ups for different tests (and so it may be an advantage to apply them all to one sample) these are separate tests to evaluate specific characteristics of the sample being tested. This part of IEC 62552 does not specify a procedure to generalize the results from sample test results to a prediction of the characteristics of the whole population from which that sample was selected.
TC1-Technical Committee for Electrical and Electronic
33 DMMS IEC 62552-1 : 2015 Household refrigeration appliances- Characteristics and test methods Part : 1 General Requirements This part of IEC 62552 specifies the essential characteristics of household refrigerating appliances, cooled by internal nature convection or forced air circulation and establishes test methods for checking the characteristics.
For the purposes of declaration, the tests defined in this part of IEC 62552 are considered to be type tests to assess the fundamental design and operation of a refrigerating appliance. This part of IEC 62552 does not define requirements for production sampling of conformity assessment of certification.
This part of IEC 62552 does not define a regime for verification testing as this varies by region and country. When verification of the performance of a refrigerating appliance of a given type in relation to this standard is necessary; it is preferable, wherever preticable that all the tests specified be applied to a single unit. This test can also be made individually for the study of a particular characteristic.
TC1-Technical Committee for Electrical and Electronic
32 DMMS IEC 62271-200 : 2011 High-voltage switchgear and control gear- Part 200: AC metal-enclosed switchgear and control gear for rated voltages above 1 kV and up to and including 52 kV TC1-Technical Committee for Electrical and Electronic
31 DMMS IEC 61058-1: 2016 Switches for appliances- Part 1:General requirements TC1-Technical Committee for Electrical and Electronic
30 DMMS IEC 61008-1 : 2013 Amendment 2 Residual current operated circuit-breakers without integral over current protection for household and similar uses (RCCBs) – Part 1: General rules TC1-Technical Committee for Electrical and Electronic
29 DMMS IEC 61008-1 : 2012 Amendment 1 Residual current operated circuit-breakers without integral over current protection for household and similar uses (RCCBs) – Part 1: General rules Delete Note 5 and replace it by the following paragraph and new Note 5:
For RCCBs incorporated in or intended only for association with socket-outlets the requirements the of this standard may be used as far as applicable in conjunction with the requirements of IEC 60884-1 or the national requirements of the country where the product is placed on the market.
NOTE 5 RCCBs incorporated in or intended only for association with socket – outlets can either meet IEC 62640 or this standard.
TC1-Technical Committee for Electrical and Electronic
28 DMMS IEC 61008-1 : 2010 Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) – Part 1: General rules TC1-Technical Committee for Electrical and Electronic
27 DMMS IEC 60969 : 2016 Self-ballasted compact fluorescent lamps for general lighting services – Performance requirements This document specifies performance requirements together with test method and conditions required to show compliance of self-ballasted compact fluorescent lamps intended for general lighting services.
This document applies to self-ballasted compact fluorescent lamps of voltages> 50 V and all power rating with lamp caps complying with IEC 60061-1.
NOTE Some features of this document could be applicable to self-ballasted compact fluorescent lamps or voltages ≤ 50 V and to other types of self-ballasted gas discharge lamps.
The requirements of this document relate only to type testing
The performance requirements specified in this document are additional to the safety requirements specified in IEC 60968
It can be expect that self-ballast compact fluorescent lamps which comply with this document will start and operate satisfactorily at normal conductions ( voltages between 92% and 106% of rated supply voltage ambient air temperature of between – 10·C and 40 ·C and in a luminaire complying with IEC 60598-1)
TC1-Technical Committee for Electrical and Electronic
26 DMMS IEC 60968 : 2015 Self-ballasted fluorescent lamps for general lighting services – Safety requirements This International Standard specifies the safety and interchangeability requirements together with the test methods and conditions required to show compliance of tubular fluorescent lamps with integrated means for controlling starting and stable operation ( self- ballasted fluorescent lamps)
These lamps are intended for domestic and similar general lighting purposes having a rated voltage of 50 V to 250 V having a rated frequency of 50 Hz or 60 Hz and having IEC 60061-1 compliant caps.
For a cap –holder system not specifically mentioned in this standard the relevant information on safety rated tests provided by the manufacturer will apply.
The requirements of this standard relate only to type testing.
Recommendations for whole product resting or batch testing are given in Annex A.
This part of the standard covers photobiological safety according to IEC 62471 and IEC TR 62471-2 Blue light and infrared hazards are below the level which requires marking.
TC1-Technical Committee for Electrical and Electronic
25 DMMS IEC 60929 : 2011 AC and /or DC -Supplied electronic control gear for tubular fluorescent lamps – Performance requirements This international standard specifies performance requirements for electronic control gear for use on a.c at 50 Hz or 60 Hz and / or d.c. supplies both up to 1000 V with operating frequencies deviating from the supply frequency associated with fluorescent lamps as specified in IEC 60081 and IEC 60901 and other fluorescent lamps for high-frequency operation.
NOTE 1 Test in this standard are type tests. Requirement for testing individual control gear during production are not included.
NOTE 2 There are regional standards regarding the regulation of mains current harmonics and immunity for end- products like luminaries and independent control gear. In a luminarie, the control gear is dominant in this respect control gear together with other component s should comply with these standards.
TC1-Technical Committee for Electrical and Electronic
24 DMMS IEC 60947-2 : 2016 Low- Voltage Switchgear and Control gear- Part – 2: Circuit – Breakers TC1-Technical Committee for Electrical and Electronic
23 DMMS IEC 60335-2-98 : 2008 Household and similar electrical appliances – Safety- Part 2-98: Particular requirements for humidifiers TC1-Technical Committee for Electrical and Electronic
22 DMMS IEC 60335-2-88 : 2002 Household and similar electrical appliances – Safety- Part 2-88: Particular requirements for humidifiers intended for use with heating, ventilation, or air-conditioning systems TC1-Technical Committee for Electrical and Electronic
21 DMMS IEC 60335-2-79 : 2016 Household and similar electrical appliances – Safety- Part 2-79: Particular requirements for high pressure cleaners and steam cleaners TC1-Technical Committee for Electrical and Electronic

© Copyright by Myanmar Standard. All right Standard. Designed by World Wide Myanmar